Galvanised Roof Sheets
34/1000 box profile 0.5 thick galvanised roofing sheets are one of our most popular sheets, with each single skin sheet having 7 strong 166mm profiles across its width. With a profile height of 34mm and coverage of 1000mm when installed, these 34/1000 box profile sheets give you a simple yet strong way to cover your build. Each 34/1000 box profile sheet will give your roof a secure weatherproof lap from sheet to sheet.
- Cover Width: 1000mm when lapped
- Profile Height: 32mm
- Pitch: 200mm
- Sheet Thickness: 0.5mm or 0.7mm
- Minimum Roof Pitch: 4 Degrees
- Max Sheet Length: 8m in 0.5mm thickness and upto 10m in 0.7mm thickness
- Colours: Galvanised
Thickness
(mm) |
Weight (kg/m2) | Span Condition | Span (m) | ||||||||||||||
1.00 | 1.10 | 1.20 | 1.30 | 1.40 | 1.50 | 1.60 | 1.70 | 1.80 | 1.90 | 2.00 | 2.10 | 2.20 | 2.30 | 2.40 | |||
0.50 | 4.90 | Single | 3.47 | 2.85 | 2.38 | 2.02 | 1.73 | 1.50 | 1.23 | 1.02 | 0.86 | 0.72 | 0.62 | 0.53 | – | – | – |
Double | 2.27 | 1.96 | 1.71 | 1.50 | 1.34 | 1.19 | 1.07 | 0.97 | 0.88 | 0.81 | 0.74 | 0.68 | 0.63 | 0.58 | 0.54 | ||
Multi | 2.70 | 2.33 | 2.04 | 1.80 | 1.60 | 1.43 | 1.29 | 1.17 | 1.07 | 0.98 | 0.90 | 0.83 | 0.76 | 0.67 | 0.59 | ||
0.70 | 6.41 | Single | 6.00 | 4.92 | 4.11 | 3.48 | 2.82 | 2.28 | 1.87 | 1.55 | 1.30 | 1.10 | 0.94 | 0.81 | 0.71 | 0.62 | 0.54 |
Double | 3.83 | 3.29 | 2.86 | 2.51 | 2.22 | 1.98 | 1.77 | 1.60 | 1.45 | 1.32 | 1.21 | 1.11 | 1.03 | 0.95 | 0.88 | ||
Multi | 4.57 | 3.94 | 3.43 | 3.02 | 2.67 | 2.39 | 2.14 | 1.94 | 1.76 | 1.61 | 1.47 | 1.35 | 1.18 | 1.03 | 0.90 |
Wind Suction Load (-ve)
Broad Flange in Compression (Single Span)
Deflection Limit L/150 *
FACTORED IMPOSED LOADS (kN/m2) (positive +ve) | |||||||||||||||||
Thickness
(mm) |
Weight (kg/m2) | Span Condition | Span (m) | ||||||||||||||
1.00 | 1.10 | 1.20 | 1.30 | 1.40 | 1.50 | 1.60 | 1.70 | 1.80 | 1.90 | 2.00 | 2.10 | 2.20 | 2.30 | 2.40 | |||
0.50 | 4.90 | Single | 3.90 | 3.22 | 2.71 | 2.31 | 1.99 | 1.73 | 1.52 | 1.27 | 1.07 | 0.91 | 0.78 | 0.68 | 0.59 | 0.51 | – |
Double | 3.67 | 3.04 | 2.55 | 2.17 | 1.87 | 1.63 | 1.44 | 1.27 | 1.13 | 1.02 | 0.92 | 0.83 | 0.76 | 0.69 | 0.64 | ||
Multi | 4.59 | 3.80 | 3.19 | 2.72 | 2.34 | 2.04 | 1.79 | 1.59 | 1.42 | 1.27 | 1.15 | 1.04 | 0.95 | 0.86 | 0.75 | ||
0.70 | 6.41 | Single | 6.02 | 4.98 | 4.18 | 3.56 | 3.07 | 2.68 | 2.32 | 1.93 | 1.63 | 1.39 | 1.19 | 1.03 | 0.89 | 0.78 | 0.69 |
Double | 6.34 | 5.24 | 4.40 | 3.75 | 3.24 | 2.82 | 2.48 | 2.19 | 1.96 | 1.76 | 1.59 | 1.44 | 1.31 | 1.20 | 1.10 | ||
Multi | 7.93 | 6.55 | 5.51 | 4.69 | 4.05 | 3.52 | 3.10 | 2.74 | 2.45 | 2.20 | 1.98 | 1.71 | 1.49 | 1.30 | 1.15 |
Notes:
- This table has been produced for roof cladding applications. However, it can be safely used for wall cladding.
- Safe Imposed loads factored by 1.6 Wind suction loads factored by 1.4
- Deflection limit applied to imposed loads –L/200
- Deflection limit applied to suction loads –L/150
CCP recommend the use of 0.7mm thick material for roof cladding
Reviews
There are no reviews yet.